COLD ROOM BREAKDOWN? 24/7 Emergency Repairs — 069 268 0988 · info@reyds.co.za
Service Hub · 24/7 Johannesburg

Defrost System Repairs Johannesburg

Defrost failures are the single biggest cause of ice build-up and cooling loss in cold and freezer rooms. We repair the full defrost system — heaters, timers, sensors and drains.

Fault Symptoms
  • [01]Ice build-up on the evaporator
  • [02]Defrost not clearing
  • [03]Water leak from the unit
  • [04]Temperature rising after defrost
Possible Causes
  • [01]Defrost heater failure
  • [02]Defrost timer or controller fault
  • [03]Defrost termination sensor failure
  • [04]Drain line freeze or blockage
Professional Diagnostic Process

We test each heater for continuity, verify the defrost schedule, check the termination sensor and inspect the drain line and heater.

Repair Process

We replace failed heaters, recalibrate or replace controllers, clear drains and install drain line heaters where needed.

Frequently Asked Questions

Why does ice keep returning after I defrost manually?

Manual defrost doesn't fix the failed defrost system — the ice returns because the heater, timer or sensor is still faulty.

Is a water leak related to defrost?

Very often. A frozen or blocked defrost drain causes water to leak inside the room.

Can defrost be adjusted to suit my load?

Yes. We set defrost frequency and duration to match your actual operating conditions.